A 10 kwatt, 480V , single phase 60Hz, 24 pole motor has an stator winding resistance of 0.1 ohm from line-to-neutral. The rotor is not a permanent magnet but a separately powered electromagnet (field wind-ings) that takes .5 A at 120 V. (The power to run this field is considered a loss) The friction losses, in-cluding windage, are 15 kW. The core losses are 20 kW. a) Determine the output (line ) current based on input wattage and voltage. b) Calculate the I2R resistance loss due to the field windings and the I2R loss due to the main windings. c) Determine the output power (kW) d) Calculate the efficiency.
A sinusoidal voltage wave of real amplitude B0, and frequency w, and phase constant B, propogate in the forward z direction toward the shorted load end in a lossless transmission line of characteristic impedance Z0.
Consider LTI system S with impulse response h(t) = u(t) - u(t-2). A) Let x1(t) = d/dt(u(t) - u(t-2)). What is the output of the system B) Let x2(t) = cos(pi*t). What is the output of the system
Prompt the user to enter a letter indicating Celsius or Fahrenheit C or c indicates that temperature entered is in Celsius. F or f indicates that temperature entered is in Fahrenheit.
Evaluate the TL parameters. Include the effect of the earth as ideal. Do not incorporate the effect of the shield wires.
Determine the transfer function for a first order low pass filter with a cutoff frequency of 1000 radians/sec (note radians and not Hertz) and a pass band gain of 1 using the following types.(a) Butterworth type(b) Chebyschev type
Express the sequence x(n)={1 n=0 , 2 n=1 , 3 n=2 , 0 else} 1- Express the signal as a sum of weighted and shifted unit impulse sequence. 2- Express the signal as a sum of weighted and shifted unit step sequence
You are working with a design team on a new product and are assigned to design the power supply. The requirements for the power supply are as follows: Input AC: 115 V AC +- 10%, 50-60 Hz Outputs: +5 V DC at 100 ma, +-12 V DC at 50 ma
A 150MW alternator generates an open-circut line-t0-line voltage of 12kV at nomial DC excitiation. When the terminals are placed in short-circuit the resulting current per phase is 8000A. a) Calculate the approximate value of the synchronous reacta..
Let x[n], y[n] and w[n] denote three finite-lenght sequences of lenghts N, M, and L, respectively with the first sample of each sequence occuring at n=0. What is the lenght of the sequence x[n] * y[n] * w[n]
What connectivity is required for both parties? Use your textbook and the Interne to research your answer. Which option would you suggest and why?
What is the maximum symbol rate that the twisted pair line can carry without ISI? 256-QAM modulation is used on the link. How many bits are conveyed by each symbol?
an electrical transformer dissipates heat equivalent of 3000 kW/h. the inlet and outlet temperatures of the cooling water are 55C and 15C respectively. calculate the mass of the cooling water in a minute.