Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
A) Calculate the fugacity of liquid hydrogen sulphide in contact with its saturated vapor at 25.5C and 20 bars.
(B) The vapor pressure of pure water at 310.6 K is 6.455 kPa. Compute the fugacity of pure liquid water at 310.6 K when it is under a pressure of 100 bars, 500 bar, and 1000 bar. [Volume 7 of the International Critical Tables (McGraw-Hill, New York, 1929) gives values of 6.925, 9.175, and 12.966 kPa, respectively, for these conditions.]
Determine the tensions developed in wires , and and the angle required for equilibrium of the 30-lb cylinder E and the 60-lb cylinder F.
a carnot heat pump refrigerator operates between -7 and 29 . it has an input power of 3.5kw. determine a the
determine the work and heat transfer, each in kJ. sketch the process on p-v and T-s coordinates. Associate the work and heat transfer with areas on these diagrams.
The 200 lb box is pulled up using a force P (in the following picture). The static coefficient of friction between the box and the truck's floor is 0.4. What is the maximum and minimum load required to keep the box in equilibrium condition? If it sta..
a car of mass 1775 kg travels with a velocity of 100 kmh. find the kinetic energy. how high should it be lifted in the
a water line is planned to connect a new reservoir to an existing water treatment plant. the average water surface
a large storage tank contains 500000 l of milk. milk enters the tank through a 0.05 m diameter pipe at a velocity of 3
steam flowing through a long thin-walled pipe maintains the pipe wall at a uniform temperature of 500k. the pipe is
billiard ball a of mass. ma0.400kg moving with speed va1.80ms strikes ball b initially at rest of mass mb0.500kg. as a
Calculate, using the psychometric equations presented in class, the humidity ratio, enthalpy, specific volume, and dew point of air at 27.4°C dry-bulb temperature and 43% relative humidity at standard atmospheric pressure (101.325 kPa). Verify your ..
a hydrocooling unit can cool fruits and vegetables from 30 to 5 oc at a rate of 20000 kgh under the following
superheated water vapor initially at 15 bar and 440degc is cooled at constant pressure to a saturated vapor state and