A solar water heater operating at steady state heats water

Assignment Help Mechanical Engineering
Reference no: EM13712200

A solar water heater operating at steady state heats water from 900F to 1200F. The panel is 3600 Btu/hr. Determine 1) the mass flow rate of the water in lb/min and 2) the volume of 1200F water after 1 hour in gallons.

Reference no: EM13712200

Questions Cloud

The tensional force of the string is in position : The 2 kg ball is releast from rest in position 1 with the string horizontal. The length of the string is L =2m and theta 40 degree. The ball's velocity when it is in position 2? The tensional force of the string is in position 2?
What should be the minimum horsepower of the lathe : A 3 in. diameter low strength, stainless steel cylindrical part is to be turned on a lathe at six hundred rpm. With a depth of cut of .3 inches and a feed of .025 in/rev. what should be the minimum horsepower of the lathe?
Quality and the total mass of the refrigerant in the tank : A 5-ft 3 rigid tank contains a saturated mixture of refrigerant-134a at 50 psia. If the saturated liquid occupies 20 percent of the volume, determine the quality and the total mass of the refrigerant in the tank
Determine the magnitude of the bending moment : An 80-mm × 40-mm rectangular beam is made of heat treated AISI 4340. On the tension side of the beam, a transverse crack of length 10 mm is discovered. Determine the magnitude of the bending moment M that will cause brittle fracture.
A solar water heater operating at steady state heats water : A solar water heater operating at steady state heats water from 90 0 F to 120 0 F. The panel is 3600 Btu/hr. Determine 1) the mass flow rate of the water in lb/min and 2) the volume of 120 0 F water after 1 hour in gallons.
Simple steam power plant with a mass flow rate : The steady state operation for a simple steam power plant with a mass flow rate of 1 kg/s is shown in the figure. Determine 1) the thermal efficiency of the process and 2) mass flow rate of cooling water in kg/s (assume condenser is well insulated)
Calculate the cross-sectional area of a single micron : For any precipitation-hardened alloy, like an al-cu alloy, the strengthening of the alloy depends on the size and number of the precipitates. Calculate the cross-sectional area of a single 10-micron (10-5 m) diameter spherical precipitate. Determine ..
Air flows isentropically through convergent-divergent : Air flows isentropically through a convergent-divergent passage with inlet area 5.2 cm^2, minimum area 3.2cm^2 and exit area 3.87 cm^2. At the inlet the air velocity is 100m/s, is 680 kPa, and temperature 345 K.
Heat exchanger operating at steady state as saturated liquid : Refrigerant 134a at a flow rate of 0.5 lb/s enters a heat exchanger operating at steady state as a saturated liquid at 0 0F and exits at 20 0F. A separate air stream enters at 120 0F and exits at 77 0F. The heat exchanger is insulated such that there..

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  Steam at 95 bar and 400 c is supplied in turbine the

steam at 95 bar and 400 c is supplied in turbine. the condenser pressure is 0.035 bar. if the plant operates as a

  What is velocity of plate b right after impact set up a

the 8lb ball a is released from rest 10ft height see figure. at the end of the travel ball will impact a 6lb plate b.

  Calculate re and verify that its smaller than 2300 if its

crude oil flowing from the exit of a pump 1 through a 1000 km longl and 0.5m diameterd pipe. the pipe fills a tank

  In what way does asme code 1592 extend the asme boiler and

in what way does asme code 1592 extend the asme boiler and pressure vessel code? what are the limits of code case

  For flow over a circular cylinder as shown below the

for flow over a circular cylinder as shown below the velocity outside of boundary layer can be estimated to beux 2

  Derive laplace transform by integration from basic integral

Derive Laplace transform by integration from basic integral definition. Do not use laplace transform tables or associated theorems. Refer to standard integral tables.

  The exiting flow which is completely mixed is at 50 degree

air at 40 degree c and 1 atm at volumetric flow rate of 1.5 m3s is joined with co2 at 120 degree c and 1 atm in pipe

  A gate is 05 m wide and 06 m tall and is hinged at the

a gate is 0.5 m wide and 0.6 m tall and is hinged at the bottom. on one side the gate holds back a 0.5 m deep body of

  Water flows at 50oc inside a 25-cm-inside-diameter tube

1.water flows at 50oc inside a 2.5-cm-inside-diameter tube such that hi 3500 wm2 oc. the tube has a wall thickness of

  What is the total heat transfer rate watts from the pipe

a horizontal stainless steel conductivity k 15 wmk circular pipe of outside and inside diameters of 0.50 m and 0.45 m

  Calculate the isentropic work process 1-2s the actual work

air at mass flow rate of 10 kgs at 1 atm 300 k point1 enters an adiabatic compressor and exists at 8 atm 600 k point 2.

  Determine the volume of chamber

the entire assembly is placed in an environment whose temperature is 200c. determine the volume of chamber 1 when thermodynamic equillibrium has been estabilished.

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd