A new building to be located in a cold climate is being designed with a basement that has an L=200 mm thick wall. Inner and outer basement wall temperatures are t=20 c and t=0 c respectively. the architect can specify the wall material to be either aerated concrete block with k= 0.15 W/m.K or stone mix concrete. To reduce the conduction heat flux through the stone mix wall to a level equivalent to that of the aerated concrete wall, what thickness of extruded polystyrene sheet must be applied onto the inner surface of the stone mix concrete wall? Floor dimensions of the basement are 20 m * 30 m, and the expected rental rate is $50/m2/month. What is the yearly cost,in the terms of lost rental income, if the stone mix concrete wall with polystyrene insulation is specified?
the basis of a design project which will be completed. you should therefore think carefully about which of the
a random sample of 25 resistors from a large production run has a sample mean value of 1001.5 ohms and a sample
a rigid tank contains air at 600 kp a absolute pressure and 18? c . what is the change in pressure if the temperature
a 32 lb weight is attached to the end of a spring with spring constant k 24 lbf. if the resistive force is 10 dxdt
a beam of rectangular cross section is 200 mm deep 100 mm wide and 3 m long. it is simply supported at each end. it has
Calculate the force of attraction between a K+ cation and a O2- anion, the centers of which are separated by a distance of 1.5 nm.
What is a 90 percent confidence interval for the standard deviation of the thickness of a washer produced by this procedure?
consider a finite wing with an aspect ratio of 7 the airfoil section of the wing is a symmetric airfoil with an
a bullet moving at a speed of 1000 fts has its speed reduced to 900 fts when it passes through a board. determine how
steam is to be condensed in the condenser of a steeam power plant at a temperature of 60c with cooling water from a
A refrigerating plant operating between temprature limit of 253k and 307k provides 4.5kJ/s of refrigerating effect. If the refrigerating efficiency of the plant is 0.76. calculate the power required to drive the plant.
steam is the working fluid in an ideal reheat rankine cycle. steam enters the first-stage turbine at 8.0 mpa 480oc and